P2 PCR laboratorija za biosigurnost

P2 PCR laboratorija za biosigurnost

It is mainly used for primary health services, diagnosis and research. The hazard level of the experimental subjects is II (medium individual hazard, limited group hazard), which is specifically defined as "can cause disease in humans or animals, but generally affect health workers and groups , Livestock or the environment will not cause serious harm to pathogens. Laboratory infections do not cause serious diseases, effective treatment and preventive measures are available, and the risk of transmission is limited."
Pošaljite upit
Chat Sada

 

Značenje P2 laboratorija P2 PCR laboratorija za biosigurnost:


Odnosi se na klasifikaciju nivoa sigurnosti bioloških laboratorija. Među svim vrstama laboratorija, laboratorija P2 je najraširenija laboratorija za biološku sigurnost. Nivoi biološke laboratorije su P1, P2, P3 i P4. Prema prirodi laboratorije odabrati odgovarajući nivo. Svjetska zdravstvena organizacija (WHO) dijeli infektivne mikroorganizme u 4 kategorije prema njihovoj patogenosti i riziku od infekcije; Prema opremi i tehničkim uslovima, biološke laboratorije se takođe dijele na 4 nivoa (općenito se nazivaju P1, P2, P3) , P4 laboratorija), nivo 1 je najniži, nivo 4 je najviši. P1 laboratorij je općenito pogodan za mikroorganizme koji nemaju patogeno djelovanje na zdrave odrasle osobe; laboratorija P2 je pogodna za mikroorganizme sa umjerenim potencijalom štetnosti za ljude i okoliš; P3 laboratorij je pogodan za ozbiljne ili čak ozbiljne infekcije uglavnom respiratornim putem. Patogeni mikroorganizmi ili njihovi toksini smrtonosnih bolesti; P4 laboratorij je pogodan za patogene mikroorganizme ili njihove toksine koji su veoma opasni za ljudski organizam, prenose se aerosolima ili nepoznati, a ne postoji efikasna vakcina ili metoda lečenja.

Upotreba P2 eksperimenta:


It is mainly used for primary health services, diagnosis and research. The hazard level of the experimental subjects is II (medium individual hazard, limited group hazard), which is specifically defined as "can cause disease in humans or animals, but generally affect health workers and groups , Livestock or the environment will not cause serious harm to pathogens. Laboratory infections do not cause serious diseases, effective treatment and preventive measures are available, and the risk of transmission is limited."


The national standard "Technical Specifications for Building Biosafety Laboratories" stipulates the following technical indicators (static) for the BLS-2 laboratory:

1. Čistoća: nema zahtjeva

2. Razlika u pritisku susjedne prostorije sa vanjskim smjerom: -20Pa

3. Temperatura: 18-27 stepeni

4. Relativna vlažnost: 30-70 posto

5. Minimalno osvjetljenje: 300LX


Gore navedeni pokazatelji su minimalni zahtjevi za uspostavljanje P2 laboratorije. Graditelj može na odgovarajući način povećati odgovarajuće pokazatelje prema stvarnim potrebama, kao što su čistoća, razlika u pritisku i drugi zahtjevi.